background image

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL DE INSTRUÇÕES 

DO GERADOR DE ONDAS 

ARBITRÁRIAS MODELO 

GV-2015 

 

Outubro/2020 

 

 

 

 

Leia atentamente as instruções 

contidas neste manual, antes   

de iniciar o uso do instrumento 

 

 

Summary of Contents for GV-2015

Page 1: ...MANUAL DE INSTRUÇÕES DO GERADOR DE ONDAS ARBITRÁRIAS MODELO GV 2015 Outubro 2020 Leia atentamente as instruções contidas neste manual antes de iniciar o uso do instrumento ...

Page 2: ... instrument is damaged due to shipping please contact the shipper and the carrier for compensation Check accessories The contents of accessories are as follows If the contents do not match or the instrument is damaged contact the dealer or the company Host Series Dual Channel Signal Generator 1pcs Accessories Power Adapter 1pcs USB cable 1pcs Signal connection cable 2pcs User manual 1pcs CD 1pcs C...

Page 3: ...gnal amplitude and frequency can be displayed simultaneously The series signal generator has excellent amplitude and frequency characteristics the appearance of this instrument is exquisite and beautiful This instrument is widely used in factories schools research institutes and laboratories The model description This series of instruments are divided into three models the main difference is the m...

Page 4: ...ulse adjustable duty cycle precise adjustment of pulse width and period triangular wave partial sine wave CMOS wave DC level set DC amplitude by adjusting offset half wave full Wave positive staircase wave anti ladder wave noise wave exponential rise exponential drop multisonic wave Symplectic pulse and Lorenz pulse and 60 arbitrary waveforms Wave length 2048 points Waveform sampling rate 266MSa s...

Page 5: ...s Flatness of amplitude 5 10MHz 10 10MHz Waveform output Output impedance 50Ω 10 typical Protection All signal outputs can work within 60 when the load is short circuited DC offset Offset adjustment range Output amplitude 2V 0 2V Output amplitude 2V 0 Output amplitude 0 2V 9 99V 9 99V 2 5V 2 5V 0 25V 0 25V Offset resolution 0 01 V Phase characteristics Phase adjustment range 0 359 9o Phase resolut...

Page 6: ...output frequency of the corresponding model of the starting point 0 01Hz and the end point Sweep direction Forward reverse and round trip Bursting function Number of pulses 1 1048575 Burst mode Manual burst CH2 burst external burst AC external burst DC General specifications Display Display type 2 4 inch TFT color LCD display Store and load Quantity 100 Position 00 to 99 00 memory location paramet...

Page 7: ...ce mount technology large scale integrated circuits high reliability long service life Prompt tone Users can turn on or off by setting program Operating characteristics All key operations knob continuous adjustment Environmental conditions Temperature 0 40 oC Humidity 80 ...

Page 8: ... 7 Chapter II Instrument Description 1 The front panel overview ...

Page 9: ... 8 2 The display interface description ...

Page 10: ... mode interface and main interface Fast switching between system setting interface and main interface The main interface is used to control the simultaneous output of channel 1 and channel 2 and in other interface key is used to control ON OFF When setting parameters you can use left and right keys to move the cursor position Select the CH1 channel to control the output of CH1 long press to set CH...

Page 11: ...again in the currently selected channel can turn on off the output of the channel and long press to place the current channel on the main display of the screen upper part Set the waveform press the front panel key to activate the waveform switching of the current channel In the active state of the waveform the knob can be quickly switched and the direction key can be used to quickly switch between...

Page 12: ... arrow keys to move the cursor to select the bit to be edited then turn the knob to adjust the value Measurement mode setting Press to switch between the two options of counting frequency and counting period via the encoder Measurement parameters frequency period positive pulse width negative pulse width duty cycle 2 2 Counting function The period number of the input signal can be calculated in re...

Page 13: ...re accurate than adjusting the duty cycle In the pulse function CH1 channel press the soft key to select the pulse width period offset and amplitude After this item is highlighted edit the item parameters by pressing the arrow keys or press the soft key and rotating the knob pulse width and period units can be switched between ns and us by pressing the key when the item is highlighted After settin...

Page 14: ... adjusted by rotating encoder Language setting Available by pressing to select English and Chinese display Synchronization The CH1 channel is used as the operation target during synchronization The parameters of the CH2 channel change following the CH1 channel parameters When the synchronization item is highlighted press the key or rotate knob to select the item to be synchronized frequency wavefo...

Page 15: ...www icel manaus com br Outubro 2020 ...

Reviews: