- 10 -
· Generator can’t work over load.It should be no more than
80%
Of rated power with load for long run.
· For 3-phase model, each load should be equal, even the
difference
Can not be over 30%,otherwise,the generator will be broken easily.
· Cable connected generator and load should conform to
national
Standard(4A/mm2)
When two or more loads are to be connected to the
generator,they shall be connected from the one requiring larger
current to that requiring a small one.
Note:
· If the generator is to be wired for house power supply, wiring
Shall be carried out by an electrician.
· Check to make sure that the wiring is correct. A wrong wiring
will cause damage to the generator and even a fire.
OK
Forbidden