background image

7

Vacuum Hose Attachment

Latch Assembly

Recovery Tank Drain

Filling the unit for use as an extractor

•  Unplug the unit.
•  Disconnect the solution and recovery tanks.
•  Remove the upper recovery tank.
•  Add water and/or chemicals to the lower solution tank.  Fill only to the fill line indicated on 

the label on the inside of the solution tank.  The tank will hold up to 3.5 gallons.

Operating the extractor

•  Attach the solution line from the vacuum hose assembly to the quick disconnect in the 

pocket at the front of the machine.

•  Attach the vacuum hose to the vacuum inlet (handle) above the recovery tank lid.
•  Turn the 3-way switch to VAC PUMP.  (Allow approximately 30 seconds for the pump to 

prime).  

•  Attach the hand tool to the hose end.  Use the hand tool to spray and recover the solution.
•  The float shut-off will disable the suction of the unit when the recovery tank is full.  The 

operator will notice a distinctive change in the sound of the vacuum motor when the shut-off 
is activated.  Empty the recovery tank and then fill the solution tank to resume cleaning. 

Emptying the Recovery Tank

•  Unplug the unit.
•  Disconnect the solution line and vacuum hose.
•  Unlatch the recovery tank from the base of the unit and remove.
•  Remove the drain plug.
•  Drain the tank over a suitable outlet for wastewater.
•  Rinse the tanks after each use.
•  Store the unit with the lid off of the recovery and allow it to air dry.

Spray Tip (included 
both an atomizer 
and fan spray tip)

Wand Hose

Wand

Extractor
Hose
Assembly

EXTRACTOR OPERATING INSTRUCTIONS

Summary of Contents for Powr-Flite NEBULA MISTER

Page 1: ...WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT Tacony Corporation All rights reserved Save These Instructions NEBULA MISTER and SPECIALTY CLEANER PFMS...

Page 2: ...nly manufacturer s recommended attachments Do not use with damaged cord or plug If unit is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service...

Page 3: ...ug that looks like the plug illustrated in sketch A GROUNDING PIN GROUNDING OUTLET RECOMMENDED GROUNDED OUTLET BOX A 2 A Do not break off or pull out the ground prong on the plug Do not attempt to rep...

Page 4: ...t Mode 1A Extraction Mode 8 9A Solution Tank 3 5 Gal 13 2 l Recovery Tank 2 5 Gal 9 5 l Dimensions 23 x 11 x 23 58 5cm x 28cm x 58 5 cm Weight 41 lbs 18 5 kg Waterlift 89 226 cm CFM CMM 104 3 Solution...

Page 5: ...for the pump to prime Use the wand with spray tip to spray the solution The atomizing nozzle that is pre installed on the wand applies smallest micron sized droplets and is perfect for most applicatio...

Page 6: ...ional fan nozzle spray tip is for application in areas like warehouses shipping carts etc where there is not a worry that the items being sprayed could get oversaturated This allows for a quicker appl...

Page 7: ...seconds for the pump to prime Attach the hand tool to the hose end Use the hand tool to spray and recover the solution The float shut off will disable the suction of the unit when the recovery tank i...

Page 8: ...Refill Solution tank Clean the screen filter on the hose in the solution tank Clean the spray jet in the hand tool Low Suction Recovery tank is full Clogged Hand Tool or hose Excessive foam Empty rec...

Page 9: ...9 3 2 5 1 10 13 60 58 52 57 59 51 15 22 54 14 18 19 47 23 24 41 40 44 39 38 34 31 32 30 33 29 35 28 36 37 27 26 25 46 45 48 21 20 50 12 56 11 53 55 9 8 7 6 4 35 22 16 49 16 53 30 43 42 17 31 61 63 62...

Page 10: ...Hose Clamp 17 71817A 2 Braided Hose 1 4 250 PSI 18 PX14A 1 Dump Valve Gasket 19 PX46 1 Lock Nut 20 X9079 1 Gasket 21 X1920BLK 1 Solution Tank 22 PC66 2 Hose Barb 1 4 H x 1 8 MPT 23 X9696 1 Gasket 24...

Page 11: ...Fitting 90 1 8 MPT x 1 4 Hose Barb 48 X8271 5 Nyloc Nut 49 X9064 1 Gasket 50 PX209 1 Foam Filter 51 7AJ004 1 Brass Anchor Connector 1 8 FPT x MPT 52 72115A 1 Washer 53 X8262 6 Screw 8 32 x 1 4 54 X90...