GROUNDING INSTRUCTIONS 

This appliance must be grounded. If it should malfunction or breakdown, grounding provides 
a path of least resistance for electric current to reduce the risk electric shock. This machine 
is equipped with a cord having an equipment -grounding conductor and grounding plug. The 
plug must be inserted into an appropriate outlet that is properly installed and grounded in 
accordance with all local codes and ordinances. 

WARNING:

 Improper connection of the equipment-grounding conductor can result in a risk 

of electric shock. Check with a qualified electrician or service person if you are in doubt as to 
whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if 
it will not fit the outlet, have a proper outlet installed by a qualified electrician. 
This appliance is for use on a nominal 115-volt circuit, and has a grounding plug that looks like 
the plug illustrated in sketch A. 

GROUNDING

PIN

GROUNDING

OUTLET

RECOMMENDED

GROUNDED

OUTLET BOX

(A)

2

A

•  Do not break off or pull out the ground prong on the plug.
•  Do not attempt to repair a warranted machine unless instructed to do so by an authorized 

shop or the factory.

•  Do not use any replacement parts except those specified on the parts list. Proper 

performance of the machine could be affected if substitutions are made.

•  Use defoamer at all times to prevent damaging the vacuum motor.
•  Do not use water in excess of 140° F (60° C). 
•  Failure to comply with the above warning instructions will void the warranty.

When using as an extractor 

•  Do not use the machine for totally dry vacuuming. This machine is not fitted with a fine dust 

filter.

•  Do not use citrus-based cleaners in this machine.
•  Do not use cleaning chemicals in this machine except those recommended for commercial 

extraction equipment.

•  The use of any chemical with abrasive additives voids the warranty.
•  Use defoamer at all times to prevent damaging the vacuum motor.
•  Do not use water in excess of 140° F (60° C). 

Summary of Contents for Powr-Flite NEBULA MISTER

Page 1: ...WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT Tacony Corporation All rights reserved Save These Instructions NEBULA MISTER and SPECIALTY CLEANER PFMS...

Page 2: ...nly manufacturer s recommended attachments Do not use with damaged cord or plug If unit is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service...

Page 3: ...ug that looks like the plug illustrated in sketch A GROUNDING PIN GROUNDING OUTLET RECOMMENDED GROUNDED OUTLET BOX A 2 A Do not break off or pull out the ground prong on the plug Do not attempt to rep...

Page 4: ...t Mode 1A Extraction Mode 8 9A Solution Tank 3 5 Gal 13 2 l Recovery Tank 2 5 Gal 9 5 l Dimensions 23 x 11 x 23 58 5cm x 28cm x 58 5 cm Weight 41 lbs 18 5 kg Waterlift 89 226 cm CFM CMM 104 3 Solution...

Page 5: ...for the pump to prime Use the wand with spray tip to spray the solution The atomizing nozzle that is pre installed on the wand applies smallest micron sized droplets and is perfect for most applicatio...

Page 6: ...ional fan nozzle spray tip is for application in areas like warehouses shipping carts etc where there is not a worry that the items being sprayed could get oversaturated This allows for a quicker appl...

Page 7: ...seconds for the pump to prime Attach the hand tool to the hose end Use the hand tool to spray and recover the solution The float shut off will disable the suction of the unit when the recovery tank i...

Page 8: ...Refill Solution tank Clean the screen filter on the hose in the solution tank Clean the spray jet in the hand tool Low Suction Recovery tank is full Clogged Hand Tool or hose Excessive foam Empty rec...

Page 9: ...9 3 2 5 1 10 13 60 58 52 57 59 51 15 22 54 14 18 19 47 23 24 41 40 44 39 38 34 31 32 30 33 29 35 28 36 37 27 26 25 46 45 48 21 20 50 12 56 11 53 55 9 8 7 6 4 35 22 16 49 16 53 30 43 42 17 31 61 63 62...

Page 10: ...Hose Clamp 17 71817A 2 Braided Hose 1 4 250 PSI 18 PX14A 1 Dump Valve Gasket 19 PX46 1 Lock Nut 20 X9079 1 Gasket 21 X1920BLK 1 Solution Tank 22 PC66 2 Hose Barb 1 4 H x 1 8 MPT 23 X9696 1 Gasket 24...

Page 11: ...Fitting 90 1 8 MPT x 1 4 Hose Barb 48 X8271 5 Nyloc Nut 49 X9064 1 Gasket 50 PX209 1 Foam Filter 51 7AJ004 1 Brass Anchor Connector 1 8 FPT x MPT 52 72115A 1 Washer 53 X8262 6 Screw 8 32 x 1 4 54 X90...

Reviews: