![background image](http://html1.mh-extra.com/html/tacony/powr-flite-nebula-mister/powr-flite-nebula-mister_operators-manual_3161775005.webp)
5
This unit can be used as either a Mister or an Extractor to use on upholstery and for detail work.
The brass atomizing nozzle provides lower saturation when spraying disinfectant while a larger
brass fan nozzle is provided for large area coverage.
NOTE: This mister is designed for use with all water-based disinfectants from
the EPA “List N”.
MISTER OPERATING INSTRUCTIONS
Filling the Mister
• Unplug the unit.
• Disconnect the solution and recovery tanks.
• Remove the upper recovery tank.
• Add water and manufacturer’s recommended solution ratio into solution tank. Fill only to the
fill line indicated on the label on the inside of the solution tank. The tank will hold up to 3.5
gallons.
Operating the Mister
• Attach misting wand pressure hose to the quick disconnect in the pocket at the front of the
machine.
• Turn the 3-way switch to MIST ONLY setting. (Allow approximately 30 seconds for the pump
to prime).
• Use the wand with spray tip to spray the solution. The atomizing nozzle that is pre-installed
on the wand applies smallest micron sized droplets and is perfect for most applications,
however proper application should still be followed to prevent over-saturation. To apply use
a natural up and down or side to side motion, slightly overlapping from one section to the
next. Do not dwell on a spot, as this will cause over-saturation.
• Refill solution tank, as recommended above, to resume cleaning.
After use
• Unplug the unit.
• Disconnect the solution line.
• Unlatch the recovery tank from the base of the unit and remove.
• Drain any remaining solution in the tank following EPA and Manufacturer guidelines for the
disposal of the chemical being used.
• Rinse the tank after each use.
• Allow it to air dry.
Note:
If the spray jets become clogged, remove and soak them thoroughly for an hour in a 8 to 1
ratio of water to white vinegar or anti-browning solution, and blow-dry. Do not use wire or pins
to clean the nozzles as this will cause the spray pattern to become distorted.