Settings room controller
You can set the setpoint temperature of each room for a specific area. Depending on
the heating mode you have selected, the unit setpoint is determined by these values
(see
Settings
). The specific room controller copies the set value as well as it copies
the new value to the website (according to the settings).
Each room controller can be switched off manually (see section
Room controller
).
Then, the status of the room changes to
inactive
and the setpoint temperatures of
the unit are to recalculate if necessary.
Settings:
Active / Inactive
Default setting:
Active
PTC element
Settings:
blocked / normal
PTC element is a simple status display (
blocked, active
). The electric heating ele-
ments are only switched on when the
heat pump
is switched on (heat pump priority
circuit) and after a delay (adjustable in
Settings
).
(Exception: individual room temperature control, see
Settings
)
PTC output
The PTC demand indicates the current demand, independent from an
active
or
normal
element.
The PTC displays only appear in the heating mode.
Display Illumination
After a certain period, the room controller will switch to standby mode. The intensity
of the display illumination is adjustable.
Window contact
If the function "Window contact" is activated in the
Settings
(see page 79 and 80),
the current status will also appear.
NOTE
In some operating modes, the average room temperature of all active rooms is determined as actual value and
compared with the setpoint (see
Settings
and
Actual value / Setpoint
,
Setpoint Temperature
).
The setpoint temperatures set on the room controllers are only significant in that, after the PTC start delay time has
elapsed (if PTC function activated under "Settings"; default setting 45min., can be adjusted in the Service level), the
reheating elements will start in those rooms where the actual temperature is below the setpoint temperature.
Therefore, the setpoint temperatures of the room controllers must be set realistically for all control modes.
10.5 Alarm Status
Description of the
Alarm status
see chapter „8 Maintenance / Remedying Faults“ page 31.
55
Genius - V 1.0
Operation/Control via Internet/App
Summary of Contents for Combi Unit Genius
Page 4: ...4 Genius V 1 0...
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ...Terminal block ventilation module 122 Appendix Genius V 1 0...
Page 123: ......