4
Description of the System
The Combi Unit
Genius
realizes the complete building services for energy efficient buildings without water-based heating system.
Modern buildings are planned with thicker envelopes. Thus, a mechanical ventilation is more and more necessary. New buildings as well
as renovated buildings have higher insulation standards with less heating loads. Consequently, conventional heating systems are often
over-dimensioned.
Systemair provides with the Combi Unit
Genius
a new designed heating system based on heating and cooling via ventilation ducts. This
can be achieved by temporarily increasing the volumetric flow in combination with an air-air/air-water-heat pump. This heat pump also
provides warm water.
Furthermore, planning and design of the building equipment can be minimized.
4.1
The Combi Unit Genius in Detail
Ventilation module
•
Rotating heat exchanger with humidity recovery
•
Heating and cooling through supply air ducts of the ventilation system
Heat pump module
•
Reversible air to air and air to water heat pump for heating, cooling and hot water
•
Steplessly controlled compressor to modulate the power exactly to the need of
heating and cooling energy
Hot water module
•
150 litres storage tank for hot water
•
Hot water production parallel to heating and cooling
•
Electric heater with 3 kW power
Figure 1:
Genius
in detail
4.1.1 Heat Pump/Cooling Circuit
A steplessly controlled air-air heat pump heats in winter and cools in summer. The heat pump adjusts its performance according to the
requirements. This guarantees an energy efficient operation. Additional air is removed from the living area via a separate duct system
and led back after treatment (heating or cooling) to living and sleeping areas. This is a pure air heating/cooling system. The extract
system remains unaffected. An odour or mass transfer from the extract air rooms into the supply air is excluded.
The hot water generation with a 150 litres drinking water tank is ensured by an additional plate heat exchanger. This ensures hot water
comfort because water treatment works during all operating modes. The water will be heated or cooled to the desired temperature on
demand.
12
Description of the System
Genius - V 1.0
Summary of Contents for Combi Unit Genius
Page 4: ...4 Genius V 1 0...
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ...Terminal block ventilation module 122 Appendix Genius V 1 0...
Page 123: ......