Synway Information Engineering Co., Ltd
Dial Tone Judging
Time
Minimum duration time for dialing tone, calculated by ms, with the default value of
1500 and the minimum value of 1300.
Busy Tone Cycle
Minimum duration time for busy tone. Range of value: 200~2000, calculated by ms,
with the default value of 700. This configuration item together with
Busy Tone
Count
judges whether a tone is busy tone or not.
Busy Tone Count
Minimum number of detected busy tone cycles for judging the hangup behavior of
the remote end. Range of value: 1~10, with the default value of 2.
Ringback Tone Cycle
at On/Off
Duration time at on and off states for judging whether a tone is ringback tone or not.
Range of value: 300~2500 at on state, 800~6000 at off state, calculated by ms, with
the default values of 1000 and 4000 respectively.
Energy of the DTMF signal sent by the gateway. Range of value: -35~15, calculated
by dB, with the default value of -11.
DTMF Energy
Energy of the tone signal sent by the gateway. Range of value: -35~15, calculated
by dB, with the default value of -25.
Tone Energy
After finishing the above general settings, you shall move on to configure the special parameters
for FXS and FXO. The table below explains the particular configuration items for FXS.
Item
Description
Maximum Time
Time length for judging a flash operation. Only a hook-flash operation which lasts a
time less than the value of this configuration item will be regarded as a valid flash
operation. Those lasting a time longer than the value of this configuration item will
be regarded as hangup operations. Range of value: 32~2000, calculated by ms,
with the default value of 700.
The mode adopted by the FXS port to send the callerID. The optional values are
FSK
and
DTMF
, with the default value of
FSK
.
CID Transmit Mode
Standard for sending FSK formatted callerID, which varies in different countries and
districts. The optional values are:
ETSI (Europe)
,
GR-30 (North America, China)
and
NIT (Japan)
, with the default value of
GR-30
. This configuration appears only
when
CID Transmit Mode
is set to
FSK
.
FSK Standard
The table below explains the particular configuration items for FXO.
Item
Description
Sets whether it is necessary to perform the two-stages dialing operation to call
the remote end via an FXO port. By default this feature is disabled.
Two Stages Dialing
Mode
After configuration, click
Save
to save your settings into the gateway or click
Reset
to restore the
configurations. If a dialog box pops up after you save your settings asking you to restart the
service, do it immediately to apply the changes. Refer to
3.8.8 Restart
for detailed instructions.
3.4.2 Dialing Rule
Considering efficiency, it is not acceptable that the gateway reports to the PBX or relevant devices
every time it receives a number. Instead, we hope that the gateway can automatically judge the
received number to see if it meets the set rule, if it is complete and if it is qualified to make
outgoing calls. Therefore, a whole dialing plan, which consists of multiple dialing rules specifying
the auto judging conditions, is required. Each dialing rule has a priority, which is used to restrict
the sequence and avoid conflict.
SMG Series Analog Gateway User Manual (Version 1.0)