![Synrad Novanta OEM ti Series User Manual Download Page 19](http://html1.mh-extra.com/html/synrad/novanta-oem-ti-series/novanta-oem-ti-series_user-manual_1421187019.webp)
TI-SERIES WATER-COOLED REAR PANEL
PAGE
|
19
Figure 2-2 ti-Series Rear panel controls and indicators. (Water-cooled ti100 shown).
ti-Series water-cooled rear panel
DC Power Cables – Re48 VDC from the DC power supply. Ti-Series DC power cables are
manufactured from #10 AWG wire and measure 1 meter (42 inches) in length.
INT (Remote Interlock) Indicator – Illuminates green to indicate that a remote interlock circuit is closed
and that lasing may be enabled (on Keyswitch lasers, a five-second delay occurs when the interlock
circuit closes). The INT indicator is red, and lasing is disabled if the interlock input is open.
TMP (Temperature) Indicator – Illuminates green to indicate that laser temperature is within limits and
that lasing may be enabled. The TMP indicator is red, and lasing is disabled if the laser’s temperature
rises above safe operating limits.
RDY (Ready) Indicator – Illuminates yellow when the laser is enabled, indicating that, after a five-second
delay, lasing will begin when a PWM Command signal is applied.
SHT (Shutter) Indicator – Illuminates blue to indicate that a Shutter Open Request signal is connected
to the User I/O port and lasing may be enabled. On Keyswitch lasers, a five-second delay occurs when a
Shutter Open Request signal is applied.
LASE Indicator – Illuminates red to indicate that the laser is actively lasing. The LASE indicator is off
when tickle pulses are being generated and illuminates red when PWM Command signal pulses are long
enough to produce laser output.
Summary of Contents for Novanta OEM ti Series
Page 1: ...ENGINEERED BY SYNRAD OEM ti Series User Manual...
Page 26: ...TI60 LABEL LOCATIONS PAGE 26 Ti60 label locations Figure 3 1 Ti60 hazard label locations...
Page 27: ...TI80 LABEL LOCATIONS PAGE 27 Ti80 label locations Figure 3 2 Ti80 hazard label locations...
Page 28: ...TI100 LABEL LOCATIONS PAGE 28 Ti100 label locations Figure 3 3 Ti100 hazard label locations...
Page 32: ...EUROPEAN UNION EU REQUIREMENTS PAGE 32 Table 3 1 Class 4 safety features...
Page 34: ...EUROPEAN UNION EU REQUIREMENTS PAGE 34 Figure 3 4 ti60 Declaration Document...
Page 35: ...EUROPEAN UNION EU REQUIREMENTS PAGE 35 Figure 3 5 ti80 Declaration document...
Page 36: ...EUROPEAN UNION EU REQUIREMENTS PAGE 36 Figure 3 6 ti00 Declaration document...
Page 55: ...INPUT SIGNALS PAGE 55 Table 4 5 Input signal table continued...
Page 65: ...DB 9 PIN DESCRIPTIONS PAGE 65 Table 4 9 Side mounted DB 9 pin descriptions continued...
Page 73: ...REMOTE INTERLOCK FUNCTIONS PAGE 73 Table 4 10 Ti60 general specifications continued...
Page 74: ...REMOTE INTERLOCK FUNCTIONS PAGE 74 Table 4 11 Ti80 general specifications...
Page 75: ...REMOTE INTERLOCK FUNCTIONS PAGE 75 Table 4 11 Ti80 general specifications continued...
Page 76: ...REMOTE INTERLOCK FUNCTIONS PAGE 76 Table 4 12 Ti100 general specifications...
Page 77: ...REMOTE INTERLOCK FUNCTIONS PAGE 77 Table 4 12 Ti100 general specifications continued...
Page 82: ...TECHNICAL DRAWINGS PAGE 82 Figure 4 29 Ti Series HS Outline and Mounting...
Page 83: ...TECHNICAL DRAWINGS PAGE 83 Figure 4 28 Ti 100p Outline and Mounting...
Page 84: ...TECHNICAL DRAWINGS PAGE 84 Figure 4 29 Ti 100 Fan Outline and Mounting...
Page 85: ...TECHNICAL DRAWINGS PAGE 85 Figure 4 30 ti Series packaging instructions...
Page 93: ...MAINTENANCE TROUBLESHOOTING PAGE 93 Table 4 14 Status Signals...
Page 99: ...MAINTENANCE TROUBLESHOOTING PAGE 99...
Page 105: ...APPENDIX PAGE 3 This page is intentionally left blank...