1
TimeSource 3100
171
TL1 Reference
097-72020-01 Issue 9: November 2003
2
5
3
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
44
Retrieve Performance Monitoring Value (cont’d)
MTIE Response Format:
<sid> <date> <time>
M <ctag>COMPLD
"SPAN-a:MTIE-a,<monval>,<vldty>
,,,,<mondat>,<montm>"
.
.
.
.
.
.
.
.
.
"SPAN-a:MTIE-a,<monval>,<vldty>
,,,,<mondat>,<montm>"
/*LINK:<link>,CMD:<command>*/
;
Note:
MTIE Data types:
•
One 15 minute bin from the last 24 hours of data. To select a 15 minute bin, enter
mondat and montm. Any mondat/montm combination outside of the past 24 hour
window is denied. Any time increment may be entered. The system rounds the value
to the nearest bin. Entered minutes of 1 to 15 correspond to the first 15 minute bin,
16 to 30 correspond to the second 15 minute bin, etc.
•
One day summary from the last 7 days of daily summaries. To select one daily
summary, enter mondat, but do not enter montm. Any mondat not in the previous 7
day window is denied.
Parameter
Value
Description
SPAN-x
x = A
E1 span A input
x = B
E1 span B input
<montype>=x
x = MTIE
Performance monitoring data type
x = TDEV
x = PHASE1S
x = PHASE1M
<mondat>=x
x = 1 to 12
Monitor date, month of the year
x = 1 to 31
Monitor date, day of the month
<montm>=x
x = 0 to 23
Monitor time, hours past midnight
x = 0 to 59
Monitor time, minutes past the hour
Summary of Contents for TimeSource 3100
Page 1: ...TimeSource 3100 GPS Primary Reference Source 097 72020 01 Issue 9 November 2003 ...
Page 49: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Page 109: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...
Page 203: ...Chapter 6 Specifications This chapter provides equipment specifications ...