140
TimeSource 3100
TL1 Reference
097-72020-01 Issue 9: November 2003
Edit Equipment (cont’d)
4.
When setting alarm integration time (SEVERITY or SERAFF), the type of alarm
(HOLDOVER, GPS, LOS, AIS, or ERROR) has to be specified. For example, ED-
EQPT::TS3100:CTAG::: ALARM=HOLDOVER, TIME=72-00, SEVERITY1=EV,
SERAFF1=NSA, SEVERITY2=MJ, SERAFF2=SA; will generate a holdover event as
soon as the condition is detected with an NSA flag. Once this condition has existed for
72 hours, TS3100 will generate a major alarm with an SA flag. These parameters can then
be verified using the RTRV-EQPT command.
5.
If the dbinit jumper is changed, the NTP password has to be re-entered.
6.
A remote oscillator must have been put into service before using the ENT-EQPT
command before setting the ENSEMBLER parameter.
7.
A span must have been put into service using the ENT-EQPT command before setting the
ENSEMBLER and SSM parameters.
8.
The span must be put into service using the ENT-EQPT command before using this
parameter.
9.
All commands on DCDUSERPORT having TID which equal SID of the DCD are
forwarded to the DCD. Similarly, the responses from the DCD are sent to the provisioned
DCDUSERPORT.
Response Format:
<sid> <date> <time>
M <ctag> COMPLD
/*LINK:<link>,CMD:<command>*/
;
Summary of Contents for TimeSource 3100
Page 1: ...TimeSource 3100 GPS Primary Reference Source 097 72020 01 Issue 9 November 2003 ...
Page 49: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Page 109: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...
Page 203: ...Chapter 6 Specifications This chapter provides equipment specifications ...