4
138
TimeSource 3100
TL1 Reference
097-72020-01 Issue 9: November 2003
E1-a
ALMOUT=b
b = AIS
Output is AIS during alarm
b =
SQUELCH
Output is squelched during alarm
b = SSM
Outputs are at “SSUT” quality level during
holdover alarm (SSM requires CAS4 or CCS4
output framing)
FRAMING=b
b=CAS
Output framing is CAS
b=CAS4
Output framing is CAS4
b=CCS
Output framing is CCS
b=CCS4
Output framing is CCS4
b=NONE
Output framing is NONE (analog) (If
ALMOUT is SQUELCH, then signal turns off
during Holdover alarm. Any other ALMOUT
option does not affect output during alarm)
OPT-a
(Additional
E1 outputs
on 990-
72020-02
systems
only)
ALMOUT=b
b = AIS
Output is AIS during alarm
b =
SQUELCH
Output is squelched during alarm
b = SSM
Outputs are at “SSUT” quality level during
holdover alarm (SSM requires CAS4 or CCS4
output framing)
FRAMING=b
b=CAS
Output framing is CAS
b=CAS4
Output framing is CAS4
b=CCS
Output framing is CCS
b=CCS4
Output framing is CCS4
b=NONE
Output framing is NONE (analog) (If
ALMOUT is SQUELCH, then signal turns off
during Holdover alarm. Any other ALMOUT
option does not affect output during alarm)
OPT-a
(990-72020-
04 systems
only)
ALMOUT=b
b = AIS
When the ESCIU detects an LOS on an input
span, AIS is output to the NE (the E1 option
does not affect output during alarm)
b =
PASSTHRU
When the ESCIU detects an LOS on an input
span, the E1 alignment sequence is passed
through to the NE with the original input alarm
Summary of Contents for TimeSource 3100
Page 1: ...TimeSource 3100 GPS Primary Reference Source 097 72020 01 Issue 9 November 2003 ...
Page 49: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Page 109: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...
Page 203: ...Chapter 6 Specifications This chapter provides equipment specifications ...