4.2.4
Station BSB000603, BSB000604, BSB000605, BSB000606
1
2
3
4
5
6
7
Figure 10 - interfaces of LPR station on a vehicle as double receiver
Technical Data and Description of Interfaces
1, 3, 5, 7
Antenna connections.
The antennas are connected to the Compact Station via a specially converted
low-loss HF cable with N-plug.
1: Antenna port no. 1,
3: Antenna port no. 2,
5: Antenna port no. 4,
7: Antenna port no. 3,
2
Network (optional).
The standard industrial Ethernet port of the station is designed as a Harting
type push pull connector.
4
Pressure equalization membrane.
The membrane prevents forming of condensation water inside the Compact
Station. The pressure equalization membrane must not be changed or covered!
6
Power supply with integrated communication ports.
Power is supplied via a Lumberg Type 0233 08 push pull connector. There is
no power switch because of the intended area of application. A 3 Ampere (slow
blow) fuse is mounted inside the Compact Station.