Commissioning
Copyright © Symeo 2012
Page 63 of 132
In mode 2b (Managed Cell) and mode 3b (TDOA) the transponder coordinates must be
stored in the configuration file of the master transponder. If the coordinates were not
transferred to Symeo before delivery or the coordinates/ transponder positions were changed
you have modify (7.2.2) and upload the configuration file for the master.
DSP
Master
Mobile unit/ base station
ARM9
DSP
RS232
User
RS232 Service
TCP/IP
User & Service
RS232
User & Service
Access via radio
remote control
(FSK channel)
Access via
TCP/IP
or serial
interface
Figure 45
– Access to the master transponder
An access to the master transponder happens via radio communication from the mobile
station.
Establish a connection between your PC and the mobile station (7.3.1 or 7.3.2)
Keep ready the following data of the master transponder: group-ID, station-ID, fsk-
channel. These data can be read out from the short ID labeled on the master
transponder. Example short-ID 10M: The first 2 digits for the cell-ID are consistent with
the group-ID. The third digit is the station-ID. The station-ID for the master is labeled with
“M”. The master has always the station-ID 30. The FSK-channel is consistent with the
cell-ID/ group-ID for the first 40 cells.
Open a FSK-connection with the master transponder: