Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Symeo
MAP
Copyright © Symeo 2012
Page 84 of 132
Figure 55 - Incorrect length value (left) and correctly adapted cable offset (right)
To get the cable offset values for all connected antennas:
If several antennas are connected to the base station, first select an antenna by pressing
the ‘A’ key
The antenna should be located in the middle of the measurement range.
Start the antenna calibrating mode by selecting menu item
View
Actions
Calibrate
antenna cable
Press the +/- keys until the transponder radii all intersect at roughly the same point.
The calculated length of the cable offset will be displayed as a blue text in the position
display window together with the number of the associated parameter. You must transfer this
value to the LPR_B.ini file (see chapter 7.4.3).
If a second, third or fourth antenna is used you have to repeat the procedure.
The antennas in the file LPR_B.ini are labeled from 0 to 3. The
calibration value for antenna 1 must entered at (0), the value for
antenna 2 at (1), etc.
If the FusionEngine operates on the mobile unit (ARM9), you have to upload the modification
in the file LPR_B.ini to the mobile unit (see chapter 7.5.1).