4-6
Phaser Series Scanner Product Reference Guide
Beeper Indications
Table 4-4. Beeper Indications
Beeper Sequence Indication
Standard Use
Short high tone A bar code symbol was decoded (if decode beeper is enabled).
4 Beeps - long low tone A transmission error has been detected in a scanned symbol. The data
is ignored. This occurs if a unit is not properly configured. Check
option settings.
5 Beeps - low tone Convert or format error.
Hi/hi/hi/lo tone RS-232 receive error.
4 Beeps - short hi Low battery.
Parameter Menu Scanning
Short high tone Correct entry scanned or correct menu sequence performed.
Lo/hi tone Input error, incorrect bar code or “Cancel” scanned, wrong entry,
incorrect bar code programming sequence; remain in program
mode.
Hi/lo tone Keyboard parameter selected. Enter value using bar code keypad.
Hi/lo/hi/lo tone Successful program exit with change in the parameter setting.