Pull the safety bond through the hole on the back of the device and over the trussing system or a safe
fixation spot. Insert the end in the quick link and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Connection with the mains
DANGER TO LIFE!
The electric connection must only be carried out by a qualified electrician
In order to connect the device to the mains, you have to install a power-plug.
The occupation of the connection-cables is as follows:
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch
with a minimum opening of 3 mm at every pole has to be included in the permanent electrical
installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with Residual Current Device (RCD) with a
maximum fault current of 30 mA.
Connect the device to the mains with the power-plug.
Lighting effects must not be connected to dimming-packs.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Cable
Pin
International
Brown
Live
L
Blue
Neutral N
Yellow/Green Earth