A-96.250.211 / 171121
AMI Sodium P
Maintenance
82
6.11.3 Replacing the EPDM Seal and the Air Inlet Tube
WARNING
Diisopropylamine is corrosive.
Read the Material Safety Data Sheets (MSDS) first.
Wear suitable protective clothing, gloves and eye/face protec
-
tion.
Avoid inhalation of DIPA vapor.
In case of contact with eyes, rinse immediately with plenty of
water eyelid wide open for at least 10 min, summon medical
advice. In case of accident or if you feel unwell, summon medi
-
cal advice immediately (show the label where possible).
1
Carefully unscrew and remove the screw cover with tube holder
from the DIPA bottle.
2
Close the DIPA bottle with the original cover.
3
Remove the EPDM seal [E] and replace it with a new one.
4
Pull the air inlet tube [F] out of the tube holder [D].
5
Push the new air inlet tube into the hole of the tube holder which
is connected with the tube 1 from air filter [B].
6
Unscrew and remove the original cover from the DIPA bottle and
screw the screw cover with tube holder on it instead.
7
Tighten the screw cover well.
A
B
C
D
E
F
Screw cover G 45
Tube 1 from air filter
Tube 2 to air lift pump
Tube holder
EPDM seal
Air inlet tube
A
B
C
E
F
D