3.31.3
CONFIGUARTION OF IN-CONVEYOR REVERSE FUNCTION
The function of the in-conveyor motor trying to reverse two times if
something gets stuck before sending an alarm can be adjusted in this
menu.
The frequency inverter setting is set using this menu. These parameters
may need adjusting to the quality of the food waste material if the
inverter gives this alarm when nothing is actually blocking the in-
conveyor or only gives this alarm when the blockage is too tight.
The screen shows the actual current reading in % and the following parameters can be adjusted:
-
Threshold current limit in % = this setting gives the current in (%) relative to actual motor current
-
Delay time current = defines delay time prior to acitavtion of comparision of threshold current and
rated motor current.
-
Run time reverse = time for infeeder to run in reverese.
-
Delay in relation to shredder start = time set for shredder to start before the in-conveyor starts.
The values set at delivery can be found in ‘Machine Specification’.
If adjustments are necessary – contact your distributor for advice before proceeding.
3.31.4
CONFIGUARTION OF SHREDDER REVERSE FUNCTION
The function of the shredder motor trying to reverse two times if
something gets stuck before sending an alarm can be adjusted in this
menu.
The frequency inverter setting is set using this menu. These parameters
may need adjusting to the quality of the food waste material if the
inverter gives this alarm when nothing is actually blocking the shredder or
only gives this alarm when the blockage is too tight.
The screen shows the actual current reading in % and the following parameters can be adjusted:
-
Threshold current limit in % = this setting gives the current in (%) relative to actual motor current
-
Delay time current = defines delay time prior to acitavtion of comparision of threshold current and
rated motor current.
-
Run time reverse = time for infeeder to run in reverese.
The values set at delivery can be found in ‘Machine Specification’.
If adjustments are necessary – contact your distributor for advice before proceeding.
FACTORY SETTINGS
The factory settings are only available for the manufacturer of the machine.
Summary of Contents for BIGHANNA T120
Page 8: ......
Page 28: ......
Page 32: ......
Page 80: ...5 3 1 START UP SCHEDULE MODEL T60 RESTAURANT WASTE...
Page 81: ......
Page 82: ...5 3 2 START UP SCHEDULE MODEL T120 RESTAURANT WASTE...
Page 83: ......
Page 84: ...5 3 3 START UP SCHEDULE MODEL T240 RESTAURANT WASTE...
Page 85: ......
Page 86: ......
Page 94: ......
Page 114: ......