3
OPERATING INSTRUCTIONS
MAIN SWITCH, RESET BUTTON AND TOUCH SCREEN.
The machine is operated from the touch screen which is placed on the top or the door of the electrical
cabinet depending on model. On the door of the lower electrical cabinet there is a main switch which
must be locked out and tagged out when the bolted covers are removed and the machine is
maintained or serviced. When the main switch on Big Hanna is turned on the fan starts automatically
and the cylinder will start rotating after minimum 30 minutes on its automatic cycle. The Big Hanna’s
biological process require 24/7 operation and should never be turned off at the main switch unless it
its serviced, repaired or taken out of service.
The blue reset button on the electrical cabinet has three modes:
Mode:
Status:
Dark blue/ Not lit up.
No alarm. Power to all motors.
Firm blue light.
Alarm is active. No power to any motors. Pressing the button will not reset the
machine – fault must be located and the source of the alarm must be
eliminated.
Flashing blue light.
Alarm is not active but button needs to be pressed in order to reset the
machine. No power to any motors.
1.
Main switch
2.
Reset button
3.
Touch screen 4” or 7”
4.
Emergency stop
Note that layout can vary between different
models. Touch screens are available in 4” or 7”.
Depending on size different options are
available.
Summary of Contents for BIGHANNA T120
Page 8: ......
Page 28: ......
Page 32: ......
Page 80: ...5 3 1 START UP SCHEDULE MODEL T60 RESTAURANT WASTE...
Page 81: ......
Page 82: ...5 3 2 START UP SCHEDULE MODEL T120 RESTAURANT WASTE...
Page 83: ......
Page 84: ...5 3 3 START UP SCHEDULE MODEL T240 RESTAURANT WASTE...
Page 85: ......
Page 86: ......
Page 94: ......
Page 114: ......