Installing the Server into a Telco Rack
To install the SuperServer 5015B-T into a Telco type rack, use two L-shaped brack-
ets on either side of the chassis (four total). First, determine how far the server will
extend out the front of the rack. Larger chassis should be positioned to balance the
weight between front and back. If a bezel is included on your server, remove it. Then
attach the two front brackets to each side of the chassis, then the two rear brackets
positioned with just enough space to accommodate the width of the rack. Finish by
sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-3. Installing the Server into a Rack
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
Summary of Contents for SUPERSERVER 5015B-T
Page 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 5015B T...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 5015B T User s Manual Notes...
Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Telco Rack...
Page 28: ...3 4 SUPERSERVER 5014C T User s Manual Notes...
Page 94: ...A 6 SUPERSERVER 5015B T User s Manual Notes...