5-20
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Watch Dog Enable/Disable
Watch Dog (JWD1) is a system monitor
that can reboot the system when a
software application hangs. Close Pins
1-2 to reset the system if an application
hangs. Close Pins 2-3 to generate
non-maskable interrupt signals for the
application that hangs. See the table on
the right for jumper settings. Watch Dog
must also be enabled in the BIOS.
Watch Dog (JWD1)
Jumper Settings
Jumper Setting Defi nition
Pins 1-2
Reset (default)
Pins 2-3
NMI
Open
Disabled
VGA Enable
Jumper JPG1 allows the user to enable
the onboard VGA connectors. The
default setting is 1-2 to enable the
connection. See the table on the right
for jumper settings.
VGA Enable (JPG1)
Jumper Settings
Jumper Setting Defi nition
1-2
Enabled (Default)
2-3
Disabled
BMC Enable
Jumper JPB1 allows you to enable the
onboard BMC (Baseboard Management)
Controller to provide IPMI 2.O/KVM
support on the motherboard. See the
table on the right for jumper settings.
BMC Enable (JPB1)
Jumper Settings
Jumper Setting Defi nition
Pins 1-2
BMC Enable (Default)
Pins 2-3
Normal
Summary of Contents for SUPERSERVER 2027TR-D70RF+
Page 1: ...SUPER SUPERSERVER Revision 1 0 SUPERSERVER 2027TR D70RF...
Page 5: ...v SUPERSERVER 2027TR D70RF SUPERSERVER Notes...
Page 10: ...x Notes SUPERSERVER 2027TR D70RF SUPERSERVER...
Page 30: ...2 12 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Page 34: ...SUPERSERVER 2027TR D70RF USER S MANUAL 3 4 Notes...
Page 54: ...4 20 SUPERSERVER servername User s Manual Notes...
Page 82: ...5 28 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Page 89: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 6 Replacing a System Fan in the Fan Housing...
Page 96: ...6 14 SUPERSERVER 2027TR D70RF USER S MANUAL Figure 6 13 Removing a System Node 1 3 1 2 1 2...
Page 138: ...7 34 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...
Page 140: ...A 2 SUPERSERVER 2027TR D70RF USER S MANUAL Notes...