Chapter 2: Server Installation
2-3
•
Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
•
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Air
fl
ow
Equipment should be mounted into a rack so that the amount of air
fl
ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
Summary of Contents for SUPERO SuperServer 5037MC-H8TRF
Page 1: ...SUPER SUPERSERVER Super MicrocloudTM 5037MC H8TRF USER S MANUAL Revision 1 0...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 54: ...5 20 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 70: ...6 16 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 92: ...7 22 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 94: ...A 2 SUPERSERVER 5037MC H8TRF User s Manual Notes...