B-2
S
UPER
S
ERVER 5037MC-H8TRF User's Manual
System Cooling
Four 8-cm system fans
System Input Requirements
AC Input Voltage: 100 - 240V AC auto-range
Rated Input Current: 11.5 - 5.5A max
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 1620W (Part# PWS-1K62P-1R) 80 Plus Bronze Certi
fi
ed
Rated Output Voltages: +12V (84A @ 100-120VAC, 100A @ 120-140VAC,
135A @ 180-264VAC), +5Vsb (4A)
Operating
Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic
Emissions:
FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic
Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN
60950/IEC
60950-Compliant
UL
Listed
(USA)
CUL
Listed
(Canada)
TUV Certi
fi
ed
(Germany)
CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate”
Summary of Contents for SUPERO SuperServer 5037MC-H8TRF
Page 1: ...SUPER SUPERSERVER Super MicrocloudTM 5037MC H8TRF USER S MANUAL Revision 1 0...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 54: ...5 20 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 70: ...6 16 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 92: ...7 22 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 94: ...A 2 SUPERSERVER 5037MC H8TRF User s Manual Notes...