2-5 Checking the Motherboard Setup
After setting up the the system, you may need to open the unit to make sure all the
connections have been made.
Note:
Before operating the system for the
fi
rst time, it is important to remove the
protective
fi
lm covering the ventilation openings on the top of the chassis. These
vents provide proper ventilation and cooling for the system.
Removing the Chassis Cover and Protective Film
1. Disconnect the chassis from any power source.
2. Remove the three screws that secure the top cover onto the chassis as il-
lustrated in Figure 2-8.
3. Lift the top cover up and off the chassis.
4. Peel off the protective
fi
lm covering the top cover and the top of the chassis
5. Check that all ventilation openings on the top cover and the top of the chassis
are clear and unobstructed.
Checking the Components and Setup
1. You may have a processor already installed into each of the motherboards.
Each processor should have its own heatsink attached. See Chapter 5 for
instructions on processor and heatsink installation.
2. Your server may have come with system memory already installed. Make
sure all DIMMs are fully seated in their slots. For details on adding system
memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking
the chassis air
fl
ow. See Chapter 5 for details on cable connections.
Summary of Contents for SUPERO SuperServer 5037MC-H8TRF
Page 1: ...SUPER SUPERSERVER Super MicrocloudTM 5037MC H8TRF USER S MANUAL Revision 1 0...
Page 5: ...v Preface Notes...
Page 14: ...1 6 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 54: ...5 20 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 70: ...6 16 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 92: ...7 22 SUPERSERVER 5037MC H8TRF User s Manual Notes...
Page 94: ...A 2 SUPERSERVER 5037MC H8TRF User s Manual Notes...