Chapter 5: Advanced Serverboard Setup
5-7
Figure 5-4. DIMM Installation
To Install:
Insert module
vertically and press down
until it snaps into place. Pay
attention to the alignment
notch at the bottom.
To Remove:
Use your
thumbs to gently push the
release tabs near both ends
of the module. This should
release it from the slot.
Top View of DDR3 Slot
Release Tab
Release Tab
Note:
Notch should
align with the receptive
key point on the slot.
Notch
Notch
Front View
Memory Population for Optimal Performance
-For a Motherboard with One CPU (CPU1) Installed
# DIMMS
CPU
Channel 1
Channel 2
Channel 3
Channel 4
4 DIMMs
CPU1
P1-1A
P1-2A
P1-3A
P1-4A
8 DIMMs
CPU1
P1-1A
P1-1B
P1-2A
P1-2B
P1-3A
P1-3B
P1-4A
P1-4B
Memory Population for Optimal Performance
-For a Motherboard with Two CPUs (CPU1 & CPU2) Installed
# DIMMS
CPU
Channel 1
Channel 2
Channel 3
Channel 4
8 DIMMs
CPU1
P1-1A
P1-2A
P1-3A
P1-4A
CPU2
P2-1A
P2-2A
P2-3A
P2-4A
16 DIMMs
CPU1
P1-1A
P1-1B
P1-2A
P1-2B
P1-3A
P1-3B
P1-4A
P1-4B
CPU2
P2-1A
P2-1B
P2-2A
P2-2B
P2-3A
P2-3B
P2-4A
P2-4B
Summary of Contents for 1022GG-TF
Page 1: ...SUPER A Server 1022GG TF USER S MANUAL Revision 1 0b ...
Page 30: ...3 4 A Server 1022GG TF User s Manual Notes ...
Page 50: ...4 20 A Server 1022GG TF User s Manual Notes ...
Page 83: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 3 Removing a Hard Drive Tray 1 1 1 2 ...
Page 114: ...7 22 A Server 1022GG TF User s Manual Notes ...
Page 116: ...A 2 A Server 1022GG TF User s Manual Notes ...