LAN1/LAN2 Enable/Disable
Change the setting of jumper JPL1
and/or JPL2 to enable or disable the
LAN1 and LAN2 onboard Ethernet
(RJ45) ports, respectively. See the
table on the right for jumper settings.
The default setting is enabled.
Watch Dog Enable/Disable
JWD1 controls the Watch Dog function.
Watch Dog is a system monitor that
can reboot the system when a software
application “hangs”. Pins 1-2 will cause
WD to reset the system if an applica-
tion hangs. Pins 2-3 will generate a
non-maskable interrupt signal for the
application that has hung. See the table
on the right for jumper settings. Watch
Dog must also be enabled in BIOS.
Note:
When enabled, the user needs to
write their own application software to
disable the Watch Dog Timer.
LAN Enable/Disable
Jumper Settings
Jumper Setting Defi nition
Pins 1-2
Enabled
Pins 2-3
Disabled
Watch Dog
Jumper Settings
Jumper Setting Defi nition
Pins 1-2
Reset
Pins 2-3
NMI
Open
Disabled
SMB to PCI Express Slots
Jumpers JI
2
C1 and JI
2
C2 allow you to
connect the System Management Bus
(I
2
C) to the PCI Express slots. Both
jumpers must have the same setting to
function correctly. The default setting is
disabled. See the table on the right for
jumper settings.
SMB to PCI-Exp
Jumper Settings
Jumper Setting Defi nition
Closed
Enabled
Open
Disabled
VGA Enable/Disable
JPG1 allows you to enable or disable
the VGA port. The default position is on
pins 1 and 2 to enable VGA. See the
table on the right for jumper settings.
VGA Enable/Disable
Jumper Settings
Jumper Setting Defi nition
Pins 1-2
Enabled
Pins 2-3
Disabled
Summary of Contents for SUPERSERVER 6016T-NTRF4+
Page 1: ...SUPERSERVER 6016T URF4 6016T NTRF4 SUPER USER S MANUAL 1 0a ...
Page 5: ...v Preface Notes ...
Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack ...
Page 23: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Page 28: ...3 4 SUPERSERVER 6016T URF4 6016T NTRF4 User s Manual Notes ...
Page 48: ...4 20 SUPERSERVER 6016T URF4 6016T NTRF4 User s Manual Notes ...
Page 87: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Removing Replacing the Power Supply ...
Page 88: ...6 10 SUPERSERVER 6016T URF4 6016T NTRF4 User s Manual Notes ...
Page 116: ...7 28 SUPERSERVER 6016T URF4 6016T NTRF4 User s Manual Notes ...
Page 118: ...A 2 SUPERSERVER 6016T URF4 6016T NTRF4 User s Manual Notes ...