A-3
Appendix B: System Specifi cations
The table below specifi es the preferred ambient temperature versus processor
support for the FatTwin F617H6-FTL+/FTPTL+ system.
Ambient Temperature versus Porcessor Support
35°C
30°C
25°C
135 W
130 W
X
1,2
X
3
115 W
X
5
X
6,7,9
X
8,10
95 W
X
1,11
X
4,13
X
12
80 W
X
12,14
X
X
Notes:
1. Only 9 HDDs per node can be populated.
2. Only 10 HDDs per node can be populated and fans running at full speed
3. Only 10 HDDs per node can be populated and fans running at full speed
4. Only 10 HDDs per node can be populated.
5. Only 9 HDDs per node can be populated and fans running at full speed
6. Only 9 HDDs per node can be populated.
7. Only 10 HDDs and one AOC per node can be populated and fans running at
Standard Mode.
8. Only 10 HDDs per node can be populated.
9. Only 11 HDDs per node can be populated with no AOC and fans running at
Standard Mode.
10. Fully populated HDDs with no AOC and fans running at full speed.
11. Only 10 HDDs and one AOC per node can be populated and fans running at
full speed.
12. Only 11 HDDs per node can be populated.
13. Only 11 HDDs per node can be populated and fans running at full speed.
14. Only one AOC per node can be populated.
Summary of Contents for FatTwin F617H6-FTL+
Page 1: ...SUPER USER S MANUAL Revision 1 1a FatTwin F617H6 FTL F617H6 FTPTL...
Page 5: ...v FatTwin F617H6 FTL FTPTL User s Manual Notes...
Page 10: ...x Notes FatTwin F617H6 FTL FTPTL User s Manual...
Page 20: ...1 10 FatTwin F617H6 FTL FTPTL User s Manual Notes...
Page 30: ...2 10 FatTwin F617H6 FTL FTPTL User s Manual Notes...
Page 34: ...FatTwin F617H6 FTL FTPTL User s Manual 3 4 Notes...
Page 86: ...5 32 FatTwin F617H6 FTL FTPTL User s Manual Notes...
Page 106: ...6 20 FatTwin F617H6 FTL FTPTL User s Manual Notes...