Chapter 6: Advanced Chassis Setup
6-19
Release Tab
Figure 6-15: Changing the Power Supply
Power Supply Replacement
The F414IS chassis utilizes two redundant power supplies (four in total). In the
unlikely event that the power supply unit needs to be replaced, one power supply can
be removed, without powering down the system. Replacement units can be ordered
directly from Supermicro (See the contact information in the Preface of this manual).
Changing the Power Supply
1. Power down the system and disconnect the AC power cord on the back of the
failed power supply.
2. Press the release tab on the back of the power supply and pull the power
supply out using the handle provided.
3. Push the replacement power supply module into the power bay until it clicks
into the locked position.
4. Plug the AC power cord back into the module and return the node to its bay
in the chassis..