Chapter 7: BIOS
7-7
OnChip SATA Type
Use this setting to set the OnChip SATA type. Options include
Native IDE
, RAID, AHCI and Legacy IDE.
RAID Codebase
This submenu appears when you choose "RAID" from the "OnChip SATA
Type" setting above. This setting allows you to select the codebase for your
RAID setup. Options are either Adaptec or
DotHill
.
SATA IDE Combined Mode
This setting allows you to
Enable
or Disable the SATA IDE combined mode.
PATA Channel Configuration
This allows you to set PATA channel configuration. Options include
SATA as
Primary
or SATA as secondary.
Primary/Secondary/Third/Fourth IDE Master/Slave
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk
drive. The options are Disabled and
Auto
.
Block (Multi-Sector Transfer)
Block mode boosts IDE drive performance by increasing the amount of data
transferred. Only 512 bytes of data can be transferred per interrupt if block
mode is not used. Block mode allows transfers of up to 64 KB per interrupt.
Select "Disabled" to allow the data to be transferred from and to the device
one sector at a time. Select "Auto" to allows the data transfer from and to the
device occur multiple sectors at a time if the device supports it. The options
are
Auto
and Disabled.
PIO Mode
PIO (Programmable I/O) mode programs timing cycles between the IDE drive
and the programmable IDE controller. As the PIO mode increases, the cycle
time decreases.
The options are
Auto
, 0, 1, 2, 3, and 4. Select Auto to allow BIOS to auto
detect the PIO mode. Use this value if the IDE disk drive support cannot be
determined. Select 0 to allow BIOS to use PIO mode 0, which has a data
transfer rate of 3.3 MBs. Select 1 to allow BIOS to use PIO mode 1, which has
a data transfer rate of 5.2 MBs. Select 2 to allow BIOS to use PIO mode 2,
Summary of Contents for A+ SERVER 1012C-MRF
Page 1: ...SUPER A SERVER 1012C MRF USER S MANUAL Revision 1 0c...
Page 5: ...v Preface Notes...
Page 9: ...ix Table of Contents Appendix A BIOS Error Beep Codes Appendix BSystem Specifications...
Page 10: ...Notes x A SERVER 1012C MRF USER S MANUAL...
Page 16: ...1 6 A SERVER 1012C MRF USER S MANUAL Notes...
Page 24: ...2 8 A SERVER 1012C MRF USER S MANUAL Figure 2 4 Installing the Server into a Telco Rack...
Page 28: ...2 12 A SERVER 1012C MRF USER S MANUAL Notes...
Page 32: ...3 4 A SERVER 1012C MRF USER S MANUAL Notes...
Page 84: ...5 32 A SERVER 1012C MRF USER S MANUAL Notes...
Page 90: ...6 6 A SERVER 1012C MRF USER S MANUAL Figure 6 3 Removing the DVD ROM Drive...
Page 92: ...6 8 A SERVER 1012C MRF USER S MANUAL Notes...
Page 110: ...7 18 A SERVER 1012C MRF USER S MANUAL Notes...
Page 112: ...A 2 A SERVER 1012C MRF GIBXF GIQXF USER S MANUAL Notes...