Chapter 4: System Safety
5-1
Chapter 5
Advanced Serverboard Setup
This chapter covers the steps required to install the H8SCM-F serverboard into
the SC512F-350B chassis, connect the data and power cables and install add-on
cards. All serverboard jumpers and connections are also described. A layout and
quick reference chart are included in this chapter for your reference. Remember to
completely close the chassis when you have finished working with the serverboard
to better cool and protect the system.
5-1 Handling the Serverboard
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent
damage to any printed circuit boards (PCBs), it is important to handle them very
carefully (see previous chapter). To prevent the H8SCM-F serverboard from
bending, keep one hand under the center of the board to support it when handling.
The following measures are generally sufficient to protect your equipment from
electric static discharge.
Precautions
•
Use a grounded wrist strap designed to prevent Electrostatic Discharge (ESD).
•
Touch a grounded metal object before removing any board from its antistatic bag.
•
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
•
When handling chips or modules, avoid touching their pins.
•
Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
•
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
Unpacking
The serverboard is shipped in antistatic packaging to avoid electrostatic discharge.
When unpacking the board, make sure the person handling it is static protected.
Summary of Contents for A+ SERVER 1012C-MRF
Page 1: ...SUPER A SERVER 1012C MRF USER S MANUAL Revision 1 0c...
Page 5: ...v Preface Notes...
Page 9: ...ix Table of Contents Appendix A BIOS Error Beep Codes Appendix BSystem Specifications...
Page 10: ...Notes x A SERVER 1012C MRF USER S MANUAL...
Page 16: ...1 6 A SERVER 1012C MRF USER S MANUAL Notes...
Page 24: ...2 8 A SERVER 1012C MRF USER S MANUAL Figure 2 4 Installing the Server into a Telco Rack...
Page 28: ...2 12 A SERVER 1012C MRF USER S MANUAL Notes...
Page 32: ...3 4 A SERVER 1012C MRF USER S MANUAL Notes...
Page 84: ...5 32 A SERVER 1012C MRF USER S MANUAL Notes...
Page 90: ...6 6 A SERVER 1012C MRF USER S MANUAL Figure 6 3 Removing the DVD ROM Drive...
Page 92: ...6 8 A SERVER 1012C MRF USER S MANUAL Notes...
Page 110: ...7 18 A SERVER 1012C MRF USER S MANUAL Notes...
Page 112: ...A 2 A SERVER 1012C MRF GIBXF GIQXF USER S MANUAL Notes...