41
Air Filter Removal
1.
Disconnect power from the flowbench.
2.
Remove the 12 cap screws that secure the filter assembly to the top of the flowbench.
3.
Remove the filter assembly from the flowbench by removing any fixtures from the assembly, and lift up
on the baseplate from the inside the 13.0” hole in the middle.
4. Disconnect the vinyl hose from the test
pressure tube on the bottom of the filter
assembly and place the filter assembly upside-
down on a worktable.
5.
Refer to the drawing for filter removal. Remove
the 6 nuts (item 9) that secure the filter end
cap (item 3). Remove the flat washers (item 7).
Remove the cable clamp (item 11) that secures
the test pressure tube (item 4) to the filter end
cap (item 3). Remove the filter end cap (item 3) and the air filter (item 2).
3
3
21"
9 1/8"
A
A
11
4
17
SECTION A-A
10
16 12
6
8
7
9
15
14
4
1
2
3
5
11 17
SEE PAGE 2
SEE PAGE 2
8
NOTE:
1. BREAK ALL EDGES
3
3
ITEM
QTY
CUT LENGTH
PART NUMBER
DESCRIPTION
1
1
SFF2400Z-1030-03 BASEPLATE, INTERCHNG RING
2
1
1065803
FILTER, 16.25X14.5X7
3
1
SFF2400Z-1034 CAP, FILTER END
4
1
SFF2500P-0127 TUBING,1/8 X 12 X .014,BRASS
5
1
SFF2400Z-1035-01 ADAPTER, ORIFICE PLATE
6
6
8.500
SF9-34-36.0-37C ROD, THREADED 1/4-28 STAINLESS
7
6
SFF9-07-W000-21B WASHER,SAE FLAT 1/4 .625 X .065 PLTD
8
12
SF9-34-N000-16B NUT,1/4-28 KEP PLTD
9
6
SF9-34-N000-44B NUT,1/4-28 NYLOCK PLTD
10
12
SF03UNC114X10X SHCS, #10-24X1-1/4
11
2
SFE4320P-8940 CLAMP,CABLE 1/8 BLK NYLON
12
1
3.625
SF3200P-0125 O-RING MATERIAL 1/8 BUNA /FT
13
1
SFINST-F1030
INSTRUCTIONS, FILTER INSTALL
14
1
SFF2500P-0127 TUBING,1/8 X 12 X .014,BRASS
15
1
.125
1037388
TUBING 1/4 OD X 1/16 W CLEAR PLASTIC/FT
16
8
SF09463
B/HD/C/S, 1/4-20 X 3/8
17
2
SFE9-28-.250-02B PHMS,8-32 X 1/4 PHIL PLTD
A
1
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF
POWER TEST INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT
THE WRITTEN PERMISSION OF POWER TEST INC. IS PROHIBITED.
B
D
C
2
3
4
A
C
B
D
2
4
3
1
ALS
DESIGNED
SIZE
B
ECO
ECO DESCRIPTION:
DATE
SEE BOM
ECO-2021-4590
UPDATE DRAWING TO PTI STANDARD;
CHANGE SFF4500P-3804 TO 1065803
18195.472
WEIGHT
DCP 03/07/2022
03/02/2022
ALS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
DECIMALS: .XX ± .01
.XXX ± .005
FRACTIONS: ± 1/32
± 1º
REV.
SHEET 1 OF 2
DATE
PART NO.
SCALE:
1:4
CAD GENERATED DRAWING,
DO NOT MANUALLY UPDATE
APPROVALS
DETAILED
REVIEWED
APPROVED
MATERIAL
FINISH
BSB
ASSY, SF1020 FILTER
W/RINGS
03/02/2022
03/02/2022
3
07/25/2018
SFF1200A-1030
Figure 6.9: Air Filter Assembly
If the baseplate has been on the flowbench for some
time, it may be difficult to remove. In this case, hit the
underside of the baseplate with your hand or a soft
rubber mallet to break the bond between the cabinet
and the baseplate. When the baseplate separates from
the gasket all the way around, lift the baseplate up and
remove it from the bench.
NOTICE
6.0 Maintenance