SUNX Limited MJE-SF4B01 No.0005-03V
-
53
-
2-5-10 Wiring Configuration for Invalid External Device Monitor Function
(Wiring Example of the Control Category 4)
This is the configuration for connecting auxiliary output and external device monitor input.
At this time, set the auxiliary output with ‘negative logic of the control output (OSSD 1, OSSD
2)’ (factory setting). The auxiliary output cannot be connected to external devices.
<For PNP output>
Interlock function
Invalid (Auto-reset)
External device monitor function
Invalid
Auxiliary output
Cannot be used
Notes: 1) Vs is the applying supply voltage.
2) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, grey, grey /
black, sky-blue / white, sky-blue / black, there is no lead wire.
* Symbols
The sensor output is selected depending on the connecting state of the shield wire. Incorrect wiring may cause the
lockout state.
Switch S1
Vs to Vs - 2.5V (sink current 5mA or less): Emission (Note 1), Open: Emission halt
K1, K2: External device (Forced guided relay or magnetic contactor)