14
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Table 5. TROUBLE-SHOOTING TABLE
Cause
Solution
Ejection of unburned pellets into the combustion chamber of the stove
Poor adjustment of the fuel-to-air
ratio from the burner controller
Contact your installer. It is necessary to set the burner
properly using gas analyzer
Utilization of low-quality pellets
Use only fuel which meets the requirements specified in the
manual. (see section 3. Fuel)
Formation of clinkers and noncombustible inclusions
Utilization of low-quality pellets
(see section 3. Fuel)
Use only fuel which meets the requirements specified in the
manual.
Low performance of the automatic
cleaning system
Increase the frequency of inclusions of self-cleaning system
Improper setting of fuel-air mixture
Adjust using gas analyzer
8. OPERATION OF PELLET STOVE
Failure to observe the installation
and operating requirements
described in the manual and
the service booklet voids the
warranty.
8.1. Operation of pellet stove Ambient
V2 4G
Ignition.
Once you have made sure that the stove
was properly installed, can perform the
initial start-up and set all parameters.
Setup can be done using the screen or via
PC using our dedicated software or data
input systems.
Burning.
The burning process takes place in the
combustion chamber of the stove, as the
fuel portions are dosed (measured) at
regular intervals by the integrated auger.
This achieves optimum combustion.
The stove performance is controlled
and operated by a temperature sensor
that measures the temperature of the
water jacket (mantle) and a temperature
sensor that measures the temperature
of the exhaust gases. Ignition and stop
are controlled by the exhaust gas sensor,
which gives information to the control
unit. The power is determined by the
adjusted maximum temperature in the
stove, as shortly before reaching it, it
starts modulating.
8.2. Important recommendations for
long-lasting and correct operation of the
stove
- For assembly and installation of the
stove follow the requirements in this
manual.
- Use only recommended in this manual
fuel.
- User`s training for operation and
maintenance of stove is performed by
an authorized installer or service shop.
Summary of Contents for BURNIT AMBIENT V2 4G 10 Plus
Page 18: ...18 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL...
Page 20: ...20 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 9 2 Controller Menus...
Page 22: ...22 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL...
Page 32: ...ISO 9001 2008 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...