25
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Parameter
code
Explanations
M e a s u r e
units
Values
8 kW
10 KW
P 000
Maximum waiting time between charging and
fire build-up phase.
minutes
25
25
P 001
Maximum time in minutes for combustion
check-up with heater off.
minutes
5
5
P 003
Auger pause during heater build-up.
seconds
: 10
50
50
P 004
Auger work during heater build-up.
seconds
: 10
15
15
P 005
Auger pause during ignition of fuel.
seconds
: 10
80
80
P 006
Auger work during ignition of fuel.
seconds
: 10
15
15
P 007
Auger pause until stable combustion.
seconds
: 10
100
100
P 008
Auger work until stable combustion.
seconds
: 10
20
20
P 010
Auger work at minimum power level.
seconds
: 10
8
9
P 018
Auger work at maximum power level.
seconds
: 10
13
16
P 019
Fan operation at shutdown.
-
200
200
P 020
Fan operation at combustion check-up.
-
169
169
P 021
Fan speed during heater build-up.
-
138
138
P 022
Fan speed during ignition.
-
141
141
P 023
Fan speed upon stable combustion.
-
143
143
P 024
Fan speed at first power level.
-
118
118
P 028
Fan speed at first/maximum power level.
-
131
131
P 029
Speed of the heat exchanger fan at check fire.
-
160
160
Table 8
Controller settings
Summary of Contents for BURNIT AMBIENT V2 4G 10 Plus
Page 18: ...18 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL...
Page 20: ...20 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL 9 2 Controller Menus...
Page 22: ...22 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL...
Page 32: ...ISO 9001 2008 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...