【M Series】Multi-turn Electric Valve Actuator
68
2021.06
Code
Warring Message
Possible Problems
Solution
08
Main Power Fault
Main power failure
a.
Power failure.
b.
PCBA failure.
a.
Check if the power sup-
ply is correct or not.
b.
Check if the wiring is
secured.
c.
Replace a new power
module.
d.
Contact the seller.
09
Abnormal Power
Supply
Main power phase
loss
a.
Phase loss for three-phase
power supply.
b.
Wrong actuator specifica-
tion.
a.
Check if the power sup-
ply is correct.
b.
Reset the voltage ac-
cording to actuator
specification.
12
Over Limit Range
Valve over stroke.
The actuator runs over the
OPEN or CLOSE limited posi-
tion at the range of higher than
100% + 216
°
or lower than 0%
– 216
°.
Adjust to the normal range.
13
Torque Overload
Jammed or stuckpipe.
a.
Valve is blocked or stuck
by foreign objects.
b.
The valve is stuck in the
valve seat when the valve
is inactive for a long time.
Operate the handwheel to
confirm if the valve is stuck
by foreign objects and re-
move them.
14
Encoder Fault
Encoder error
a.
Encoder circuit is broken.
b.
Poor external wiring con-
nection.
a.
Confirm if the wiring is
correct or not.
b.
Contact the seller.
15
Motor Temp. Fault
Motor temperature
sensor failure
The temperature sensor is
broken.
Replace a new motor.
18
Handwheel Fault
Handwheel failure
a.
Handwheel wiring is not
correct.
b.
Poor internal wiring con-
nection.
a.
Confirm if the wiring is
correct or not.
b.
Contact the seller.
Summary of Contents for M Series
Page 1: ...SY04 C001A EN APP iOS Android ...
Page 7: ... M Series Multi turn Electric Valve Actuator 4 2021 06 3 2 Nameplate Instruction Caution ...
Page 24: ... M Series Multi turn Electric Valve Actuator 21 2021 06 Settings Menu 8 1 2 ...
Page 25: ... M Series Multi turn Electric Valve Actuator 22 2021 06 ...
Page 26: ... M Series Multi turn Electric Valve Actuator 23 2021 06 ...
Page 75: ......