【M Series】Multi-turn Electric Valve Actuator
17
2021.06
6.3
Electrical Connection - Cable Connection
Terminal cross section and tightening torques
Type
Cross Section (mm
2
)
Torque (N
m)
Power terminals (L1, L2, L3) & PE connection
5
2
Control contacts (1-52)
4
1
a.
Connect cables according to the order-related wiring diagram.
Risk of electric shock in case a protective earth conductor is NOT connected!
Start running the device only after having connected the protective earth
conductor inside actuator.
b.
Tighten PE conductor firmly to PE
connection.