2-10
SPARCserver 1000 System Board Manual—October 1994
2
3. Place the SuperSPARC module on the standoffs and align the module
connector with the system board socket. For SuperSPARC module B, slide
the back panel end (the side opposite the connector) into place under the
lip of the back panel filler panel, then align the connector with the socket.
Ensure that the holes in the board line up over the pins in the filler panel.
Refer to Figure 2-5.
Caution – Ensure the heat sink does not get caught on the lip of the system
board back panel during installation. If it does, the board will not seat properly
in the backplane.
4. Hold the SuperSPARC module by the edges near the connector and firmly
but gently press the module down until the connector is fully seated.
Caution – Do not rock the module onto the socket; the plastic connector
housing may break.
5. Starting from the side opposite from the connector, press each corner of
the SuperSPARC module to ensure that it rests on the collar of the
standoff.
6. Press down on the tip insert of each standoff to lock the module in place.
2.5 SBus Card
The system board has three SBus card locations. Refer to Figure 2-6. To select
the location for an SBus card, refer to Appendix C, “General Rules for System
Configuration.”
!
!
Summary of Contents for SunSwift SPARCserver 1000
Page 6: ...vi SPARCserver 1000 System Board Manual October 1994 ...
Page 10: ...x SPARCserver 1000 System Board Manual October 1994 ...
Page 14: ...xiv SPARCserver 1000 System Board Manual October 1994 ...
Page 20: ...1 6 SPARCserver 1000 System Board Manual October 1994 1 ...
Page 68: ...C 8 SPARCserver 1000 System Board Manual October 1994 C ...
Page 72: ...Index 4 SPARCserver 1000 System Board Manual October 1994 ...
Page 74: ...SPARCserver 1000 System Board Manual October 1994 ...