Removing and Replacing System Boards and Assemblies
2-13
2
2.5.2.1 Preparing for Installation
1. Open the protective packaging and take out the SBus card.
2. Remove the adapter bracket from the SBus card rear panel.
Refer to Figure 2-8. Using a #0 Phillips screwdriver, remove the two screws
securing the adapter to the card rear panel. The adapter bracket and the
screws are not needed for this installation.
Figure 2-8
SBus Card Rear Panel with Adapter
3. Remove the black plastic card retainer shipped with the card.
Refer to Figure 2-9. Spread the ends of the retainer apart to remove it from
the card. The retainer is not needed for this installation.
Figure 2-9
SBus Card Retainer
Remove adapter
Remove screws
Card retainer