SPARCserver 1000 System Board Manual—October 1994
C
C.1.2 SuperSPARC Modules
When installing or replacing a SuperSPARC module, use the following
guidelines to verify that you have selected a valid location.
Each system board has two SuperSPARC module connectors, designated A and
B (location A is closest to the backplane connector). Refer to Figure C-1. The
modules mount above the system board on standoffs. Modules should first be
installed in the A connectors on consecutive system boards starting with the
system board in slot 0. After all of the A connectors have been filled, begin
filling the B connectors, starting with the system board in slot 0.
Figure C-1
Locations of SuperSPARC Modules
The example in Table C-1 shows how to distribute four SuperSPARC modules
on three system boards.
SuperSPARC module A
SuperSPARC module B
SPARC connectors