General Rules for System Configuration
C-3
C
C.1.3 SBus Cards
Each system board has three SBus slots. Each SBus card mounts on standoffs
above the system board. Refer to Figure C-2.
Figure C-2
SBus Card Locations
The system board in slot 0 is the system master and has a minimum required
configuration. The SCSI bus on the system master board must be terminated.
All other SBus slots are available. Each type of SBus card should be distributed
evenly between the available system boards.
If video is required, the CGSIX SBus card should be installed in slot 1 (first
available) on the system master board installed in slot 0 of the server.
Table C-1 Example of Connector and Slot Priorities
System Board Slot 0
System Board Slot 1
System Board Slot 2
Connector A
Full
Full
Full
Connector B
Full
–
–
SBus card
locations
SBus connectors
Summary of Contents for SunSwift SPARCserver 1000
Page 6: ...vi SPARCserver 1000 System Board Manual October 1994 ...
Page 10: ...x SPARCserver 1000 System Board Manual October 1994 ...
Page 14: ...xiv SPARCserver 1000 System Board Manual October 1994 ...
Page 20: ...1 6 SPARCserver 1000 System Board Manual October 1994 1 ...
Page 68: ...C 8 SPARCserver 1000 System Board Manual October 1994 C ...
Page 72: ...Index 4 SPARCserver 1000 System Board Manual October 1994 ...
Page 74: ...SPARCserver 1000 System Board Manual October 1994 ...