C-4
Sun Fire X2100 Server User Guide • April 2007
C.2.2
Using the
util.exe
GUI
1. Insert the Sun Fire X2100 Server Supplemental CD into the Sun Fire X2100 Server
DVD drive and reboot the server.
2. When the Supplemental CD Main Menu displays, select the DOS Utility option.
3. Change to the latest IPMI subdirectory:
> cd flash\bios\latest\IPMI
4. Type:
util.exe
at the prompt.
The
util.exe
Main Menu appears.
The active main menu items are described in the following sections:
■
Section C.2.2.1, “Flash Firmware” on page C-4
: This menu item gives you the
option to flash the BMC firmware.
■
Section C.2.2.2, “Lan Config” on page C-4
: This menu item gives you the option to
set or change the following LAN settings: IP address, Net Mask, Gateway, MAC
address, Broadcast ARP.
■
Section C.2.2.3, “Setting User Names and Passwords” on page C-5
: This menu
item enables you to set passwords for each of the preset user names.
C.2.2.1
Flash Firmware
To flash the firmware, do the following:
1. Select the Flash Firmware... option from the Main Menu.
You will be prompted for a file name.
Note –
When flashing to IPMI firmware v4.13, ensure the system BIOS is at v1.1.1.
2. Enter a file name in the format
xxx
.bin.
Where
xxx
is the firmware version number.
For example, firmware v4.13 will be located in the
413.bin
file.
C.2.2.2
Lan Config
To change LAN configuration, do the following:
1. Select the Lan Config option from the main menu.
The LAN Configuration Viewer screen appears.