3-4
Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
■
–48V Supply
■
PSU Ground
■
–48V Return
5. Strip 0.31 inches (8 mm) of insulation from each of the wires coming from the DC
power source (see
FIGURE 3-2
).
Do not strip more than 0.31 inches (8 mm) from each wire. Doing so will leave
uninsulated wire exposed from the DC connector after the assembly is complete.
FIGURE 3-2
Stripping the Insulation From the Wire
0.31 in. (8 mm)