6-4
Sun Fire V210 and V240 Servers Administration Guide
• December
2005
■
ALOM continues to be effective when the server operating system goes off-line.
See
TABLE
3-1
for a list of the components monitored by ALOM and the information
it provides for each.
Tip –
For additional information see the
Advanced Lights Out Management User’s
Guide
(817-5481).
6.4
POST Diagnostics
POST is a firmware program that is useful in determining if a portion of the system
has failed. POST verifies the core functionality of the system, including the CPU
module or modules, motherboard, memory, and some on-board I/O devices. POST
generates messages that can be useful in determining the nature of a hardware
failure. POST can be run even if the system is unable to boot.
POST detects most system faults and is located in the motherboard OpenBoot™
PROM. POST can be set to run by the OpenBoot firmware at power up by setting
two environment variables, the
diag-switch?
and the
diag-level
flag, which are
stored on the system configuration card.
POST runs automatically when the system power is applied and all of the following
conditions apply:
■
diag-switch? is set to true (default is false)
■
diag-level is set to min, max or menus (default is min)
POST also runs automatically when the system is reset and all of the following
conditions apply:
■
diag-switch? is set to false (default is false)
■
the current type of system reset matches any of the reset types set in post-trigger
■
diag-level is set to min, max or menus (default is min)
If
diag-level
is set to
min
or
max
, POST performs an abbreviated or extended test,
respectively.
If
diag-level
is set to
menus
, a menu of all the tests executed at power up is
displayed.
POST diagnostic and error message reports are displayed on a console.
Summary of Contents for Fire V210
Page 8: ...viii Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 10: ...x Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 12: ...xii Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 18: ...xviii Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 40: ...1 22 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 56: ...2 16 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 64: ...3 8 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 70: ...4 6 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 71: ...5 1 CHAPTER 5 SunVTS This chapter contains information about SunVTS ...
Page 76: ...5 6 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 110: ...6 34 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 114: ...Index 4 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...