1-12
Sun Fire V210 and V240 Servers Administration Guide
• December
2005
1.2.8
DVD-ROM Drive
The Sun Fire V210 and V240 servers contain a bay to accept an optional slimline
ATAPI DVD-ROM drive. The bay is located on the front panel and is accessed by
opening the bezel.
For information on DVD-ROM drive installation, see
Section
2.6, “Removing and
Replacing the DVD Drive” on page
2-12
.
1.2.9
System Configuration Card
The system configuration card (SCC) is housed in a slot behind the front bezel, next
to the On/Standby switch (
FIGURE
1-4
). The card contains unique network identity
information, including the MAC address and host ID (known as the IDPROM), and
the OpenBoot™ PROM configuration (also known as NVRAM).
The server attempts to access the SCC while booting.
■
If a properly formatted card is not present in the reader, the system does not boot.
■
If the content of the NVRAM section is invalid, the system is not initialized with
its default NVRAM configuration.
It is essential that you store the SCC safely if you have to remove it from the server,
and replace it before restarting the system.
For more information, see
Section
2.4, “Swapping a System Configuration Card
Between Servers” on page
2-6
.
TABLE
1-6
OpenBoot PROM Configuration Parameters Stored on the System
Configuration Card
Parameter
Default
Description
diag-passes
1
Defines the number of times self-test
methods are performed.
loca-mac-address?
true
If
true
, network drivers use their own
MAC address, not the server’s.
fcode-debug?
false
If
true
, include name fields for plug-in
device FCodes.
ttyb-rts-dtr-off
true
If
true
, operating system does not assert
RTS and DTR on TTYB port.
ttyb-ignore-cd
false
If
true
, operating system ignores carrier-
detect on TTYB
Summary of Contents for Fire V210
Page 8: ...viii Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 10: ...x Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 12: ...xii Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 18: ...xviii Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 40: ...1 22 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 56: ...2 16 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 64: ...3 8 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 70: ...4 6 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 71: ...5 1 CHAPTER 5 SunVTS This chapter contains information about SunVTS ...
Page 76: ...5 6 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 110: ...6 34 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...
Page 114: ...Index 4 Sun Fire V210 and V240 Servers Administration Guide December 2005 ...