![Sumitomo TYPE-71c Manual To Operation Download Page 70](http://html1.mh-extra.com/html/sumitomo/type-71c/type-71c_manual-to-operation_1390693070.webp)
4-6
<Change splice program parameter>
Select Splice Program
Touch the item once. The icon will
change its color. Then touch it again
to determine selection.
Input the value by touching number
keys, then touch “OK” ( ).
In the splice program setting screen
(page 4-1), select the program
(change the color), then touch
“Setting” icon ( ). Item select
screen is displayed.
Select Item
Splice Program
SM G652 Std.
1/2
Fusion Time
02.00 sec
003
SMF Quick
Prefusion Time
00.18 sec
SMF Quick
Arc Gap
15.00 um
SMF Quick
Over Lap
10.00 um
OK
Set Value
SM G652 Std.
Fusion Time
OK
1
7 8
2 3
9
5 6
4
0
-
+
+
0
2
. 0 0
unit
:
sec
Max.
:
+20.00
Min.
:
+00.00
Standard
:
+02.00
<Change heater program parameter>
Touch the item once. The icon will
change its color. Then touch it again
to determine selection.
Select Heater Program
40mm 0.25
1/2
Heat Up Temp. A
0215 C
003
SMF Quick
Heating Duration A
0014 sec
SMF Quick
Heat Up Temp. B
0165 C
SMF Quick
0020 sec
Heater Program
Heating Duration B
Select Item
In the heater program setting screen
(page 4-2), select the program
(change the color), then touch
“Setting” icon ( ). Item select
screen is displayed.
Input the value by touching number
keys, then touch “OK” ( ).
OK
Set Value
40mm 0.25
Heat Up Temp. A
OK
1
7
8
2 3
9
5 6
4
0
-
+
+
0
2. 1 5
unit
:
C
Max.
:
+0250
Min.
:
+0080
Standard
:
+0215
Select Heater Program
Heater Program
1/5
60mm 0.25
001
40mm 0.25
002
60mm Thin
003
004
40mm Thin
1/67
SM G652 Quick
003
SM G652 AIAS
004
PureMetro
-
SM
028
Splice Program
Select Item
SMF
SM G652 Std.
002