![Sumitomo HC-4A Technical Manual Download Page 34](http://html1.mh-extra.com/html/sumitomo/hc-4a/hc-4a_technical-manual_1390617034.webp)
Installation
28
6.
Leak check all Aeroquip couplings. See the Leak Check procedure.
7.
Read the equalization pressure. Compare it to the equalization pressure stated in the
Specifications section.
8.
Connect the other system components according to the instructions supplied for them.
Connect the cold head power cable(s) to the cold head receptacle(s) on the front of the
compressor.
After the installation procedures for all system components have been completed, startup can
begin.
Remote On/Off Cable (Optional Accessory)
A remote on/off cable can be furnished as an accessory. See the Parts section for part number.
1.
Disconnect the power to the compressor.
2.
Remove the heat shrink cap from one end of the remote on/off cable. Connect the cable to
customer’s remote switch. Use the green conductor to ground the switch box. Switch
voltage will be the same as the customer’s power source, single phase. See Figure 9,
Electrical Schematic Diagram.
3.
Connect the other end of the cable to the accessory receptacle on the compressor.
4.
Reconnect the compressor to its power source.
The system can now be operated from the compressor or from customer’s remote switch.
When using the customer’s remote on/off switch, the power switch on the compressor must
be in the stop (off) position.
5.
To verify that the cable installation is correct, close customer’s remote switch. Run the
system for one minute, then stop.
NOTE
When customer’s remote switch starts the compressor, it cannot be stopped
by
the
compressor’s power switch. Open the compressor’s circuit breaker to stop it
locally. When the compressor is started at the compressor power switch, it
cannot be stopped at the remote on/off switch.
Compressor Shipping Preparation
PREVENT EQUIPMENT DAMAGE.
Do not over tighten the shipping bolt.
PREVENT EQUIPMENT DAMAGE.
Always thoroughly drain the coolant from
the cooling circuit if the compressor is to be shipped or stored.
A shipping bolt, P/N 70498, was installed on the compressor when it left the factory. If the
compressor is to be shipped, reinstall the shipping bolt from the bottom of the compressor’s
Summary of Contents for HC-4A
Page 2: ......
Page 6: ...iv This page is intentionally blank ...
Page 10: ...4 This page is intentionally blank ...
Page 12: ...6 This page is intentionally blank ...
Page 14: ...8 This page is intentionally blank ...
Page 36: ...30 This page is intentionally blank ...
Page 38: ...32 This page is intentionally blank ...
Page 59: ...Troubleshooting 53 Figure 8 HC 4A Wiring Diagram Main Electrical Chassis and Components ...
Page 60: ...Troubleshooting 54 Figure 9 HC 4A2 Wiring Diagram Main Electrical Chassis and Components ...
Page 61: ...Troubleshooting 55 Figure 10 HC 4A and HC 4A2 Wiring Diagram Air Cooled Unit ...
Page 62: ...Troubleshooting 56 Figure 11 HC 4A Electrical Schematic ...
Page 64: ...Troubleshooting 58 Figure 13 HC 4A2 Electrical Schematic Air Cooled Unit ...
Page 68: ...Parts 62 Figure 15 Parts Identification for HC 4A 12 14 19 23 ...
Page 69: ...Parts 63 Figure 16 Parts Identification for HC 4A2 12 14 19 23 ...
Page 70: ...Parts 64 Figure 17 Parts Identification 29 28 30 31 ...