4.2.3
Asegúrese de que todas las tuberías de desagüe/acoplamientos tienen un
diámetro interno de 12 mm (1/2”) o mayor. Asegúrese de que cada tubería se
mantiene recta y de que no excede los 5m (16’).
68
4.2.1
In compressor aftercoolers / refrigerant dryers, Sullair recommend the drain is
installed directly below the separator or vessel being drained, using pipework
/ fittings with an internal diameter of no less than 19mm (3/4”) to prevent
airlocking.
If it is not possible to install directly below the separator or vessel being
drained, the lower inlet connection can be used. The upper inlet must be
connected, to a point of equal pressure above the condensate level. This will
act as a balance line and prevent the unit from airlocking.
FAILURE TO INSTALL A BALANCE LINE WILL CAUSE AN AIRLOCK AND DRAIN
WILL NOT OPERATE.
9
4.2
Connection to a Compressor Intercooler / Aftercooler or Refrigerant Dryer
Summary of Contents for SCD300