Descripción del modo de Alarma
El modo de alarma se activa cuando el purgador no puede descargar el líquido que hay en
el interior del recipiente de purgado. El modo de alarma se indica mediante un LED verde
parpadeante.
Durante el modo de alarma, el purgador continuará realizando un ciclo para eliminar el
líquido existente en el recipiente. Después de eliminar el líquido, el purgador resumirá su
operación normal y cesará el parpadeo del LED.
No descargar el líquido normalmente indica que existe una tubería de desagüe bloqueada,
una válvula bloqueada o que el modelo de purgado tiene un tamaño demasiado pequeño
para la aplicación en la que se le pretende utilizar.
Modelo Alto (A)
Ancho (B)
Largo (C)
Alto (D)
Peso
SCD300
179 mm (7”) 201 mm (7,9“)
168 mm (6,5”) 230 mm (9”) 6,5 Kg (14,3 lbs)
SCD400
179 mm (7”) 231 mm (9“)
168 mm (6,5”) 230 mm (9”) 7,4 Kg (16,3 lbs)
SCD500
179 mm (7”) 651 mm (25,5“) 168 mm (6,5”) 230 mm (9”) 13,6Kg (29,9 lbs)
(D)
(A)
(B)
(C)
2.0 PESOS Y DIMENSIONES
60
6.
OPERATING THE DRAIN
17
• Ensure drain is installed in accordance with sections 4 and 5 of this manual.
• Switch on power supply. LED will illuminate Green indicating power on.
• Ensure air pressure is between 2 bar g (29 psi g) and 16 bar g (232 psi g).
• Slowly open inlet / balance line isolation valves.
• Test solenoid valve operation by depressing the test button.
• Drain operation will now be fully automatic.
7. MAINTENANCE RECOMMENDATIONS
•
Regular maintenance is not required on this product, however it is recommended
that the drain is isolated and removed annually to replace diaphragm.
•
Clean internally and externally with a damp cloth. DO NOT rinse or wash internal /
external components with solvents.
•
Use maintenance kit part no. SCDMK3 02250112-822
8. FAULT DIAGNOSIS TABLE
Green LED is off
Continuous flashing of
green LED
Air bleed from outlet port
Condensate discharge not
occurring, LED is on. Unit only
works when test button is
depressed
Check power supply
Check fuse
Press test button and observe
Check that outlet pipes and internal
passages are not blocked
Check sizing
Debris trapped under diaphragm
Damage to diaphragm
Unit may be air locking due to
incorrect installation
Locate and eliminate supply fault.
Replace fuse if required.
Drain operation suggests an LED
problem exists - contact supplier.
Remove drain bowl and clean any
debris from valve and outlet pipes.
Ensure drain is not undersized and
being presented with too much
condensate.
If problem persists, contact
supplier.
Press test button to clear.
Replace diaphragm with
maintenance kit.
Refer to instructions in section 4 of
this manual.
Should the above fail to clear the problem, or a problem occurs that is not shown in
the fault diagnosis table, please contact your supplier or Sullair service department
before removing or returning the product.
Problem
Check
Action