Section 2
DESCRIPTION
22
2.11 LAMP INDICATORS
Embedded into the front panel schematic of the
compressor are several lamps. Pressing the lamp
test key will light all the lamps for 3 seconds. Each
LED lamp has the following purpose.
P1
- (Line pressure) If lit steady, signifies that P1 is
being displayed, if flashing denotes the presence of
an alarm.
P2
- (Sump pressure) If lit steady, signifies that P2
is being displayed, if flashing denotes the presence
of an alarm.
P3
- Injection oil pressure (Pressure after oil filter)
Same as P1 & P2 except for P3.
P4
- (Pressure before oil filter)
dP1
- (Separate differential pressure) If lit steady,
signifies that DP1 is being displayed, if flashing
denotes replacement of separator is needed.
dP2
- (Oil filter differential pressure)
dP3
- (Oil differential pressure)
T1
- (Dry side discharge temperature) If lit steady,
signifies that T1 is being displayed, if flashing
denotes the presence of an alarm.
T2
- (Discharge temperature) If lit steady, signifies
that T2 is being displayed, if flashing denotes the
presence of an alarm.
T3
- (Oil temperature) If lit steady, signifies that T3
is being displayed. For monitoring only.
T4
- (Interstage temperature) If lit steady, signifies
that T4 is being displayed, if flashing denotes the
presence of an alarm.
For T1, T2 and T4, shutdown points are at 255ºF
(124ºC) with a 30 second delay, and 275ºF (135ºC )
immediate.
MOTOR
- If flashing, indicates the motor overload
contact has opened.
INLET FILTER
- If flashing, indicates that inlet filter
maintenance is needed.
OIL FILTER
- If flashing, indicates that oil filter
maintenance is needed.
POWER ON
- Lit if 120VAC power is applied to the
Supervisor II.
ON
- If lit steady, the compressor is running. If flash-
ing, indicates that the compressor is armed but
stopped because of restart timer not expired,
remote stop or sequence stop. The compressor
may start at any time.
AUTO
- If lit steady, the compressor is running and
in auto mode. If flashing, indicates that the com-
pressor is armed but stopped because of restart
timer not expired, remote stop or sequence stop.
The compressor may start at any time.
Summary of Contents for LS20TS
Page 6: ......
Page 20: ...Section 2 DESCRIPTION 14 Figure 2 4A Control System Diagram Functional Components ...
Page 21: ...Section 2 DESCRIPTION 15 Figure 2 4B Control System Diagram START ...
Page 22: ...Section 2 DESCRIPTION 16 Figure 2 4C Control System Diagram MODULATION ...
Page 23: ...Section 2 DESCRIPTION 17 Figure 2 4D Control System Diagram FULL LOAD ...
Page 24: ...Section 2 DESCRIPTION 18 Figure 2 4E Control System Diagram UNLOAD ...
Page 40: ...NOTES 34 ...
Page 50: ...NOTES 44 ...
Page 53: ...NOTES 47 ...
Page 56: ...Section 8 ILLUSTRATIONS AND PARTS LIST 50 02250135 237R01 8 4 AIR INLET SYSTEM ...
Page 58: ...Section 8 ILLUSTRATIONS AND PARTS LIST 52 02250135 237R01 8 4 AIR INLET SYSTEM ...
Page 72: ...Section 8 ILLUSTRATIONS AND PARTS LIST 66 02250138 950R01 8 9 DISCHARGE SYSTEM ...
Page 74: ...Section 8 ILLUSTRATIONS AND PARTS LIST 68 02250138 950R01 8 9 DISCHARGE SYSTEM ...
Page 76: ...Section 8 ILLUSTRATIONS AND PARTS LIST 70 02250138 950R01 8 9 DISCHARGE SYSTEM ...
Page 78: ...Section 8 ILLUSTRATIONS AND PARTS LIST 72 02250139 578R00 8 10 CONTROL START SYSTEM ...
Page 80: ...Section 8 ILLUSTRATIONS AND PARTS LIST 74 02250139 578R00 8 10 CONTROL START SYSTEM ...
Page 82: ...Section 8 ILLUSTRATIONS AND PARTS LIST 76 02250137 724R02 8 11 CONTROL PANEL ...
Page 84: ...Section 8 ILLUSTRATIONS AND PARTS LIST 78 8 12 ENCLOSURE AND ENCLOSURE DECALS ...
Page 86: ...Section 8 ILLUSTRATIONS AND PARTS LIST 80 8 13 DECAL GROUP ...
Page 88: ...Section 8 ILLUSTRATIONS AND PARTS LIST 82 8 13 DECAL GROUP ...
Page 90: ...Section 8 ILLUSTRATIONS AND PARTS LIST 84 8 13 DECAL GROUP ...
Page 92: ...Section 8 ILLUSTRATIONS AND PARTS LIST 86 8 14 DECAL LOCATIONS OPEN WATER COOLED ...
Page 94: ...Section 8 ILLUSTRATIONS AND PARTS LIST 88 8 15 DECAL LOCATIONS CONTROL BOX ...
Page 97: ...NOTES 91 ...